Tankless Water Heater Flow Rate Calculator
Calculate the required flow rate and BTU/kW capacity for tankless water heaters. Size units properly based on fixture demands and simultaneous usage patterns.
Tankless Water Heater Sizing Guide
Flow Rate Demand
Add up all fixtures that might run simultaneously
Account for peak usage times and household size
Temperature Rise
Inlet temperature varies by region (45-70°F)
Higher temperature rise requires more BTU/kW
Unit Selection
Gas units typically handle higher flow rates
Electric units require adequate electrical service
System Configuration
Fixture Selection
Kitchen
Bathroom
Laundry
Other
Sizing Guidelines
Typical Flow Rates
• Shower: 1.5-4.0 GPM
• Kitchen Sink: 2.2 GPM
• Bathroom Sink: 1.5 GPM
• Washing Machine: 3.0 GPM
• Dishwasher: 1.5 GPM
Simultaneous Use Factors
• 1-2 People: 60-70%
• 3-4 People: 70-80%
• 5+ People: 80-90%
• Commercial: 85-100%
Regional Inlet Temperatures
• Northern States: 45-55°F
• Central States: 50-60°F
• Southern States: 60-70°F
Tankless Water Heater Sizing Formulas & Methods
Step-by-Step Sizing Process
- 1. Flow Rate Assessment: Calculate total GPM demand from all fixtures
- 2. Simultaneous Use Factor: Apply usage factor based on household size and patterns
- 3. Temperature Rise: Determine ΔT between inlet and target temperatures
- 4. BTU/kW Calculation: Calculate required heating capacity using flow and temperature rise
- 5. Unit Selection: Choose unit with adequate flow and heating capacity
- 6. Performance Verification: Ensure unit maintains target temperature at peak flow
Core Heating Calculations
Gas Unit BTU Requirement:
BTU/hr = GPM × 8.33 × ΔT × 60
Where 8.33 = lbs/gallon of water, 60 = minutes/hour
Electric Unit kW Requirement:
kW = (GPM × 8.33 × ΔT) / (3412 × η)
Where 3412 = BTU/hr per kW, η = efficiency
Adjusted Flow Rate:
Q_adjusted = Q_total × Simultaneous_Factor
Accounts for realistic usage patterns
Performance & Efficiency
Temperature Rise Calculation:
ΔT = T_target - T_inlet
Varies seasonally with groundwater temperature
Flow Rate Limitation:
Q_max = BTU/(500 × ΔT)
Maximum flow at given temperature rise
Electrical Service Requirement:
Amps = (kW × 1000) / Voltage
For 240V: I = kW × 4.17
Sizing Factors & Considerations
Simultaneous Use Factors:
1-2 People: 60-70%
3-4 People: 70-80%
5+ People: 80-90%
Commercial: 85-100%
Regional Inlet Temps:
Northern: 45-55°F
Central: 50-60°F
Southern: 60-70°F
Winter: -5°F typical drop
Safety Factors:
Flow capacity: +10-20%
BTU/kW: +15-25%
Cold climate: +20-30%
High altitude: Consult manufacturer
Variable Definitions & Standards
Q = Flow rate (GPM)
ΔT = Temperature rise (°F)
BTU/hr = British Thermal Units per hour
kW = Kilowatts
η = Efficiency (decimal)
T_inlet = Incoming water temp
T_target = Desired outlet temp
GPM = Gallons per minute
Gas efficiency: 80-96%
Electric efficiency: 95-99%
Standard temp: 120°F residential
Max temp: 140°F (code limit)
Tankless Unit Performance & Selection Guide
Gas vs Electric Performance Comparison
Natural Gas Units
- • Flow Range: 6-11+ GPM typical
- • BTU Range: 140,000-240,000+
- • Efficiency: 80-96%
- • Pros: High flow, lower operating cost
- • Cons: Venting required, higher install cost
Electric Units
- • Flow Range: 3-6 GPM typical
- • kW Range: 18-36 kW
- • Efficiency: 95-99%
- • Pros: No venting, precise control
- • Cons: Lower flow, high electrical demand
Application Sizing Guidelines
Small Residential (1-2 People)
- • Flow: 4-6 GPM
- • Gas: 140,000-160,000 BTU/hr
- • Electric: 18-24 kW
- • Serves: 1 shower + 1 faucet
Medium Residential (3-4 People)
- • Flow: 6-8 GPM
- • Gas: 160,000-199,000 BTU/hr
- • Electric: 24-32 kW
- • Serves: 2 showers or 1 shower + appliances
Large Residential (5+ People)
- • Flow: 8-11+ GPM
- • Gas: 199,000+ BTU/hr
- • Electric: 32+ kW (multiple units)
- • Serves: Multiple simultaneous demands
Tankless Water Heater Flow Rate Questions & Answers
How do I figure out what flow rate I actually need?
Start by listing everything that uses hot water in your house and their flow rates - shower heads (check the label, usually 1.5-2.5 GPM), kitchen sink, dishwasher, washing machine, etc. Then think about what realistically runs at the same time. Most families don't run everything simultaneously, so you can usually use 70-80% of the total as your sizing flow rate. The calculator helps you figure this out, but if you're unsure, err on the high side - it's better to have capacity you don't need than to run out of hot water.
Why does inlet water temperature matter so much for sizing?
Because the heater has to raise the water from whatever temperature it comes in at to your target temperature. If your groundwater is 45°F in winter and you want 120°F hot water, that's a 75°F rise. But if you're in Florida where groundwater might be 65°F, you only need a 55°F rise - that's about 25% less heating capacity needed. Cold climates need bigger units or you'll get lukewarm water when it's really cold outside. This is why northern installers often go up a size or two from what the calculator suggests.
Should I go with gas or electric, and what's the real difference?
Gas units generally handle higher flow rates and cost less to operate, but they need venting and gas lines. Electric units are simpler to install but hit a wall on flow rate - most residential electric service can't handle more than about 6 GPM worth of tankless heating. If you need serious flow (multiple showers running), you're probably looking at gas or multiple electric units. Electric makes sense for smaller applications or if running gas lines is really expensive. Don't forget that big electric units might need electrical service upgrades.
What happens if I undersize the unit?
You'll get flow, but the temperature will drop when demand exceeds the unit's capacity. So if you size for 6 GPM and try to pull 8 GPM, you might get lukewarm water instead of hot. Some units will modulate and maintain temperature by reducing flow, which means lower pressure at your fixtures. Either way, it's not great. The good news is that most quality units will give you consistent temperature up to their rated capacity - it's when you exceed that capacity that things get dicey.
How accurate are these BTU and kW calculations?
Pretty accurate for the basic physics - water takes a specific amount of energy to heat up, and these formulas account for that. Where it gets tricky is real-world efficiency and installation factors. A unit might be rated at 85% efficiency, but if it's not installed perfectly or the venting isn't optimal, you might see less. Also, the calculations assume steady state - starting from cold, units take a moment to get up to temperature. For sizing purposes, these numbers are solid, but don't expect them to match your gas bill exactly.
Can I install multiple smaller units instead of one big one?
Absolutely, and sometimes it's the better choice. You can run multiple units in parallel for higher total flow, or install them at different locations (like one for the master bath, one for the rest of the house). Multiple units give you redundancy - if one breaks, you still have hot water. The downside is higher installation cost and more maintenance. For electric units, multiple smaller units might be easier on your electrical service than one huge unit that needs a massive dedicated circuit.
What's the deal with simultaneous use factors?
It's basically diversity - not everyone uses hot water at exactly the same time. A family of four might have fixtures totaling 12 GPM, but realistically they're not all running simultaneously. The simultaneous use factor accounts for this. Smaller households (1-2 people) might use 60-70% because there are fewer people to coordinate. Larger families might hit 80-90% during peak times like morning showers. Commercial applications often use 85-100% because there's less coordination of usage patterns.
How do I know if my electrical service can handle a big electric tankless unit?
Look at your main electrical panel - if it's 200 amps, you can probably handle up to about 24-30 kW worth of tankless (assuming your other loads aren't maxed out). 100-amp service might handle 18 kW. The rule of thumb is that the tankless shouldn't be more than about 40% of your total service capacity. You'll also need adequate wire size and breakers. For anything over 24 kW, you should have an electrician do a load calculation to make sure you won't overload your service during peak usage.
Why do some calculators give different answers for the same inputs?
Different assumptions about efficiency, safety factors, and simultaneous use. Some calculators are conservative and add big safety margins, others are more aggressive. Manufacturer calculators sometimes push you toward their larger units. The basic physics is the same everywhere, but the interpretation varies. Our calculator tries to be realistic about actual usage patterns while still giving you adequate capacity. When in doubt, compare a few calculators and if they're all in the same ballpark, you're probably good.
What about high altitude or really cold climates?
Both can affect performance. High altitude reduces gas unit efficiency and might affect venting, so you may need a larger unit or special high-altitude models. Really cold climates (where groundwater gets below 45°F) need bigger units to handle the increased temperature rise. Some northern installers automatically go up one size from what the calculation suggests. If you're above 4,000 feet elevation or in an area where groundwater temperature drops below 45°F in winter, talk to local installers about their sizing practices.
Why are tankless units more expensive upfront than tank units?
You're paying for the technology - sophisticated gas valves, heat exchangers, electronic controls, and sensors that can instantly modulate heat output. Plus installation costs are often higher because you might need bigger gas lines, new venting, or electrical upgrades. The units themselves cost 2-3 times more than tanks, but they last longer and save energy over time.
Related Plumbing Calculators
Water Heater Sizing Calculator
Compare tankless requirements with traditional tank water heater sizing.
Gas Line Sizing Calculator
Size gas lines to supply high BTU demands of tankless water heaters.
Hot Water Recirculation
Design recirculation systems for tankless installations.
Water Flow Rate Calculator
Calculate flow rates through distribution pipes for tankless systems.
Fixture Unit Load Calculator
Calculate simultaneous hot water demand for tankless sizing.
BTU Heating Load Calculator
Calculate BTU requirements for combination heating/hot water systems.
Complete Your Tankless System Design
Tankless water heater installation requires comprehensive system analysis. Use these calculators for complete design: